Illustrated title card for the guide: PoE+/PoE++ Input Budget Chart: In-Wall AP Passthrough Ports

Sheet No. 323 · PoE

PoE+/PoE++ Input Budget Chart: In-Wall AP Passthrough Ports

Compare PoE+ and PoE++ wattage at the switch and AP input, see UniFi and Omada passthrough requirements, and check your switch's shared PoE budget.

Choose the PoE input your in-wall access point (AP) specifies for passthrough. PoE+ enables output on the U7 In-Wall, while the U6 Enterprise In-Wall requires PoE++ for output. U7 In-Wall specs · U6 Enterprise In-Wall specs

PoE input budget at the AP

The chart pairs each PoE mode’s maximum power per switch port with the corresponding AP input budget at that power level. TP-Link PoE switch guide · Omada PoE setup guide

Upstream PoE modeMax. power per switch portAP input budget at port maximum
PoE+ (802.3at Type 2)30 W25.5 W
PoE++ (802.3bt Type 3)60 W51 W
802.3bt Type 490 W71.3 W

Passthrough output by AP model

Look up the exact AP model and hardware version. Use the output listed for the input mode you plan to use, and connect the downstream device to the designated PoE output port.

In-wall APUpstream input for passthroughPublished passthrough outputManufacturer specs
UniFi U7 In-WallPoE+One PoE output portUbiquiti
UniFi U6 Enterprise In-WallPoE++One PoE output portUbiquiti
Omada EAP725-Wall (US V1)PoE+ (802.3at)7 W on the 2.5 GbE downlinkOmada
Omada EAP725-Wall (US V1)802.3bt15.4 W on the 2.5 GbE downlinkOmada

The U6 Enterprise In-Wall can run on PoE+. Use PoE++ when the AP also needs to power a device through its output port. U6 Enterprise In-Wall specs

Check the downstream device and switch budget

  1. Compare the downstream load with the AP’s output. A device that requires 10 W exceeds the EAP725-Wall’s 7 W passthrough limit on PoE+. Omada calls for 802.3bt input above 7 W on this version. Also check the device’s PoE input requirements against the AP’s output specs. Omada EAP725-Wall (US) V1 specs
  2. Check the switch port and the switch-wide budget. Confirm the selected port provides the AP’s required PoE mode. Subtract the power already allocated to other ports from the switch’s total PoE budget. Compare the remainder with the allocation needed for the AP’s uplink. TP-Link PoE switch guide · Omada PoE setup guide

Evidence and limits. TP-Link’s IEEE 802.3at and 802.3bt guidance, Omada’s PoE setup guide and EAP725-Wall US V1 specs, and Ubiquiti’s U7-IW and U6-Enterprise-IW specs were checked on November 27, 2026. No hardware tests were performed for this guide.

Sources

  1. TP-Link PoE Switch Guide
  2. Omada PoE Network Setup Guide
  3. UniFi U7 In-Wall tech specs
  4. UniFi U6 Enterprise In-Wall tech specs
  5. Omada EAP725-Wall (US) V1 specifications

More sheets from the book